Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Korean Journal of Anesthesiology ; : 570-575, 2019.
Article in English | WPRIM | ID: wpr-786242

ABSTRACT

BACKGROUND: Air-QⓇ laryngeal mask airway (LMA) is a second-generation supraglottic airway device (SAD) providing adequate airway control despite the unfavorable airway anatomy in children. Several studies have assessed it as a conduit for tracheal intubation and compared its efficacy with that of other SADs, but there are no studies comparing the laryngeal view with midline and rotational insertion techniques of Air-Q. Therefore, this study compared the fiber-optic bronchoscopic (FOB) assessment of the Air-Q position using these two insertion techniques.METHODS: This randomized controlled trial included 80 patients of the American Society of Anesthesiologists physical status I/II of either sex (age group 5–12 years, weight 10–30 kg), who were scheduled for elective surgery in the supine position under general anesthesia. The patients were randomly subjected to rotational and midline technique groups (n = 40, each), and appropriate sized Air-Q, based on the weight of the patient, was inserted using the technique allocated to each patient. Time taken and number of attempts for successful insertion of the devices and any complications after removal of device were studied.RESULTS: FOB grade 1 (ideal position) was seen in 29/40 (72.5%) and 19/40 (47.5%) children subjected to the rotational and classic midline techniques, respectively (P = 0.045). The time taken to successfully insert the Air-Q was significantly lesser in the rotational technique group (7.2 ± 1.5 s) than in the classic midline technique group (10.2 ± 2.1 s) (P < 0.001), whereas complications were similar in both groups.CONCLUSIONS: The rotational technique was associated with better FOB view, and was faster than the classic midline technique of Air-Q insertion in pediatric patients.


Subject(s)
Child , Humans , Airway Management , Anesthesia, General , Intubation , Laryngeal Masks , Prospective Studies , Supine Position
2.
Korean Journal of Anesthesiology ; : 570-575, 2019.
Article in English | WPRIM | ID: wpr-917455

ABSTRACT

BACKGROUND@#Air-QⓇ laryngeal mask airway (LMA) is a second-generation supraglottic airway device (SAD) providing adequate airway control despite the unfavorable airway anatomy in children. Several studies have assessed it as a conduit for tracheal intubation and compared its efficacy with that of other SADs, but there are no studies comparing the laryngeal view with midline and rotational insertion techniques of Air-Q. Therefore, this study compared the fiber-optic bronchoscopic (FOB) assessment of the Air-Q position using these two insertion techniques.@*METHODS@#This randomized controlled trial included 80 patients of the American Society of Anesthesiologists physical status I/II of either sex (age group 5–12 years, weight 10–30 kg), who were scheduled for elective surgery in the supine position under general anesthesia. The patients were randomly subjected to rotational and midline technique groups (n = 40, each), and appropriate sized Air-Q, based on the weight of the patient, was inserted using the technique allocated to each patient. Time taken and number of attempts for successful insertion of the devices and any complications after removal of device were studied.@*RESULTS@#FOB grade 1 (ideal position) was seen in 29/40 (72.5%) and 19/40 (47.5%) children subjected to the rotational and classic midline techniques, respectively (P = 0.045). The time taken to successfully insert the Air-Q was significantly lesser in the rotational technique group (7.2 ± 1.5 s) than in the classic midline technique group (10.2 ± 2.1 s) (P < 0.001), whereas complications were similar in both groups.@*CONCLUSIONS@#The rotational technique was associated with better FOB view, and was faster than the classic midline technique of Air-Q insertion in pediatric patients.

3.
SJA-Saudi Journal of Anaesthesia. 2014; 8 (2): 279-281
in English | IMEMR | ID: emr-142214

ABSTRACT

We report a case of unusual presentation of transurethral resection of prostate [TURP] syndrome. A 58-year-old male patient with grade III benign hypertrophic hyperplasia was scheduled for TURP under spinal anesthesia. At 120 min of surgery, the patient presented with atypical symptoms of tightness in the chest with difficulty in breathing. The electrolyte analysis revealed an acute hyponatremia [serum Na+ 95 mEq/l]. Patient was successfully treated with rapid infusion of 3% hypertonic saline along with furosemide.


Subject(s)
Humans , Male , Transurethral Resection of Prostate , Saline Solution, Hypertonic , Acute Disease , Furosemide
4.
SJA-Saudi Journal of Anaesthesia. 2014; 8 (3): 402-405
in English | IMEMR | ID: emr-152562

ABSTRACT

A 32-year-old Indian female 38 weeks pregnant, with a history of multiple sclerosis since 2008 was admitted in obstetric ward for safe confinement. She had a history of diminution of vision in both eyes and limb weakness, relapsing - remitting type with movement-induced muscle spasms, in all the four limbs. Her symptoms were usually diplopia, difficulty in vision and ataxic gait. Sh was then treated with methylprednisolone. She was on oral dimethyl fumarate trial, which was stopped at the beginning of pregnancy. Presently, she was completely asymptomatic. Epidural anesthesia with an indwelling catheter was administered with 15 ml of 0.25% bupivacaine in 5 ml increments. A total of 3 mg of epidural morphine was given for post-operative analgesia. The surgery evolved without any intercurrences and patient was discharged from the hospital 72 h after surgery without worsening of her symptoms. We report a safe anesthetic management of a patient with MS undergoing cesarean section with low dose epidural bupivacaine with the addition of morphine for post-operative analgesia

SELECTION OF CITATIONS
SEARCH DETAIL